(1) atc cnc router magazine cannot be turned or rotated

The reasons are as follows:

1.The loose coupling of the motor shaft and the worm shaft; 

2.The inverter should be checked whether the input or output voltage of the inverter is normal or not; 

3.The PLC has no control output and may be the failure of the relay in the interface board; 

4.The connection is too tight, or the butter is sticky;

5.The grid voltage is too low (should not be lower than 370 V);

6.The motor rotation fault; 

7 Transmission mechanism error.


(2) atc cnc router tool sleeve cannot clamp the tool

The reasons are: 

Loose adjustment nut on the knife sleeve or the spring is too loose, resulting in insufficient clamping force; the tool is 


overweight.


(3) atc cnc router knife sleeve is not up and down

The reasons are as follows: 

improper adjustment of the device or excessive processing error causes the position of the fork to be incorrect; due to 


improper installation or improper adjustment of the limit switch, the feedback signal is incorrect.


(4) atc cnc router tool sleeve can not be removed or stay for a period of time to disassemble

The reasons are: 

the knife sleeve is loose at 90° and the air pressure is insufficient; the shaft of the knife sleeve is rusted.